Keohi HDTV

 

 

Powered by Keohi Web Design

[BRAND SPECIFIC][TOSHIBA][SERVICE MENU]

61H70 Defaults

<< Back to Service/Designer Menu Page

Tip from Todd Mathews:  Todd adds that SVM Power connector is Gray/Gray/White on connector P704 on main board.  This set has an SVM board on each tube labeled SVM-R, SVM-G, SVM-B. The main board (SVM-G) gets power from the P704 connector on the main board. It takes less than 5 minutes to take out the six screws on the back and unplug the SVM power connector. It in about the middle of the board and the only set of wires (aprox 18-20 gauge) with two gray wires and one white wire. A quick unplug and SVM is gone.

SERVICE SETTINGS

BCUT

40H

BDRV

30H

BLKE

22H

BLKS

06H

BRTC

89H

CNR

08H

GCUT

40H

HCP

00H

HIT

50H

HPHA

2DH

HPOS

60H

LIN

15H

OPT1

50H

OPT2

ODH

PARA

29H

PCNT

10H

PCOL

15H

PHUE

40H

PIOF

07H

PQOF

06H

PYOF

3BH

RCUT

24H

RDRV

34H

SCNT

10H

SCOL

0EH

TNTC

45H

TVOP

OOH

VCEN

70H

VCP

0AH

VFC

00H

VPOS

04H

VPS

0AH

VSC

10H

WID

1AH